All Categories : EDA Tutorials Bookmark and Share

Title : MT-007: Aperture Time, Aperture Jitter, Aperture Delay Time – Removing the Confusion
Company :
Date : 25-Mar-2009
Rating :
Downloads : 51

Rate This File
5 Stars
4 Stars
3 Stars
2 Stars
1 Star

Perhaps the most misunderstood and misused ADC and sample-and-hold (or track-and-hold) specifications are those that include the word aperture. A simple model is shown in Figure 1, and the most essential dynamic property of a SHA is its ability to disconnect quickly the hold capacitor from the input buffer amplifier. Historically, the short (but non-zero) interval required for this action is called aperture time (or sampling aperture), ta. The actual value of the voltage that is held at the end of this interval is a function of both the input signal slew rate and the errors introduced by the switching operation itself.
User Reviews More Reviews Review This File
Featured Video
Jobs
GPU Design Verification Engineer for AMD at Santa Clara, California
Senior Firmware Architect - Server Manageability for Nvidia at Santa Clara, California
CAD Engineer for Nvidia at Santa Clara, California
Senior Platform Software Engineer, AI Server - GPU for Nvidia at Santa Clara, California
Design Verification Engineer for Blockwork IT at Milpitas, California
Sr. Silicon Design Engineer for AMD at Santa Clara, California
Upcoming Events
SEMICON Japan 2024 at Tokyo Big Sight Tokyo Japan - Dec 11 - 13, 2024
PDF Solutions AI Executive Conference at St. Regis Hotel San Francisco - Dec 12, 2024
DVCon U.S. 2025 at United States - Feb 24 - 27, 2025



© 2024 Internet Business Systems, Inc.
670 Aberdeen Way, Milpitas, CA 95035
+1 (408) 882-6554 — Contact Us, or visit our other sites:
AECCafe - Architectural Design and Engineering TechJobsCafe - Technical Jobs and Resumes GISCafe - Geographical Information Services  MCADCafe - Mechanical Design and Engineering ShareCG - Share Computer Graphic (CG) Animation, 3D Art and 3D Models
  Privacy PolicyAdvertise