Leti and Partners Show Path to Achieve Ultimate Performance in Nanosystems

 

GRENOBLE, France, March 10, 2016 – A team from Leti and the University of Grenoble-Alps, along with Leti’s international partners, have developed a technique to diagnose performance problems of nanoresonators, nanosensors used in industry, research and medical diagnosis. 

These nano-electrical-mechanical systems (NEMS) have never been able to operate at full capacity. The discrepancy between the theoretical limit of detection and the degraded practical limit has not been explained until now. The researchers were able to understand this phenomenon thanks to their new approach, which is featured in this month’s Nature Nanotechnology, published Feb. 29, and are working on a solution to this problem.

Nanoresonators are comprised of a cantilever (middle) vibrating at a certain resonance frequency. The vibration is translated into an electrical signal that transmits information electrically. These systems can detect a mass or force. With mass, they can identify and quantify particles or gases. With force, the systems can be used for medical imaging or scanning surfaces on a subatomic scale to study, for example, the interactions of DNA and proteins.

Comprised of a kind of "nano string", nanoresonators vibrate at a certain resonance frequency. This frequency changes when gas molecules, or biological particles, accrete on the surface of the nanoresonators, where they are identified for applications such as medical diagnosis. The tiny dimensions of these devices (less than one millionth of a meter in width) allow highly sensitive detection (Figure 1).

This resolution, however, still has a detection limit because "background noise" interferes with the measurements. The observed background noise, which researchers have always considered to be intrinsic to the systems (Figure 2), nevertheless remains well above that predicted by theory. But because it has been impossible to understand this phenomenon, researchers historically have not pursued an explanation.

The Leti team and partners reviewed all frequency stability measurements reported in the scientific literature, and showed that a difference of several orders of magnitude existed between the commonly accepted theoretical limit and experimental measurements.

In addition to assessing this gap, the researchers developed a technique to evaluate nanoresonators by studying this problem with their own resonators in very pure monocrystalline silicon.

To measure mass or force, researchers measured the resonant frequency – the frequency of the electrical signal emitted by the nanoresonator. This frequency is determined by the material and the geometry of the device. Like any signal, it is degraded by random noise, which affects the useful signal. This widely accepted theoretical limit can be quantified but not eliminated. This limit is still much lower than that observed for all devices worldwide.




Figure 2: Note: "bottom-up" refers to a manufacturing technique using chemical growth rather than by etching a base material, which is used, for example, for carbonnanotubes or graphene. © CEA-Leti

The resonance frequency of a nanoresonator is theoretically fixed because it is determined by the nature of its source material and its geometry. By causing vibrations at several other defined frequencies near its resonant frequency, Leti researchers have demonstrated that in addition to anticipated theoretical background noise, another effect interferes with the resolution limit that the device detects:  its resonant frequency varies slightly.

These resonance frequency fluctuations result from the extreme sensitivity of these systems, which detect very small variations in mass and force, but also are very sensitive to any variation in temperature, movement of molecules on their surface and other factors. These parameters can no longer be ignored at these scales, because they limit the performance of nanoresonators. For example, an infinitesimal change in temperature can vary the parameters of the material of the device and thus its frequency. These changes can be rapid and unpredictable.

This research highlights that none of the advanced theoretical hypotheses for the causes of the resonance frequency fluctuations explains the level of these fluctuations.

“The experimental technique developed by Leti and its partners, which is the subject of a pending patent application, allows researchers to assess the loss of resolution and identify whether it is caused by an intrinsic limit to the system or from another fluctuation,” said Leti CEO Marie Semeria. “If it is from another fluctuation, it is correctable. The team will therefore continue to explore the physical origin of these fluctuations, through various experiments, in order to drastically improve the performance of its nanoresonators.”

Also participating in this study were the Federal Polytechnic School of Lausanne (EPFL, Switzerland), the Indian Institute of Sciences in Bangalore (India) and the California Institute of Technology (Caltech, USA). The paper’s authors received funding from the Carnot Institute (NEMS-MS project) and the European Union (grant ERC Consolidator, Enlightened project).

References: “Frequency fluctuations in silicon nanoresonators”, Marc Sansa et al., Nature Nanotechnology, February 2016, DOI: 10.1038/NNANO.2016.19

About Leti (France)

As one of three advanced-research institutes within the CEA Technological Research Division, Leti serves as a bridge between basic research and production of micro- and nanotechnologies that improve the lives of people around the world. It is committed to creating innovation and transferring it to industry. Backed by its portfolio of 2,800 patents, Leti partners with large industrials, SMEs and startups to tailor advanced solutions that strengthen their competitive positions. It has launched 59 startups. Its 8,500m² of new-generation cleanroom space feature 200mm and 300mm wafer processing of micro and nano solutions for applications ranging from space to smart devices. With a staff of more than 1,900, Leti is based in Grenoble, France, and has offices in Silicon Valley, Calif., and Tokyo. Follow us on www.leti.fr and @CEA_Leti.

 



Read the complete story ...
Featured Video
Jobs
Design Verification Engineer for Blockwork IT at Milpitas, California
CAD Engineer for Nvidia at Santa Clara, California
Senior Firmware Architect - Server Manageability for Nvidia at Santa Clara, California
GPU Design Verification Engineer for AMD at Santa Clara, California
Senior Platform Software Engineer, AI Server - GPU for Nvidia at Santa Clara, California
Upcoming Events
SEMICON Japan 2024 at Tokyo Big Sight Tokyo Japan - Dec 11 - 13, 2024
PDF Solutions AI Executive Conference at St. Regis Hotel San Francisco - Dec 12, 2024
DVCon U.S. 2025 at United States - Feb 24 - 27, 2025



© 2024 Internet Business Systems, Inc.
670 Aberdeen Way, Milpitas, CA 95035
+1 (408) 882-6554 — Contact Us, or visit our other sites:
AECCafe - Architectural Design and Engineering TechJobsCafe - Technical Jobs and Resumes GISCafe - Geographical Information Services  MCADCafe - Mechanical Design and Engineering ShareCG - Share Computer Graphic (CG) Animation, 3D Art and 3D Models
  Privacy PolicyAdvertise